Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Abdom Radiol (NY). 2019 Feb;44(2):482-492. doi: 10.1007/s00261-018-1745-3.

Abstract

Purpose: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH).

Study type: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland-Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change.

Results: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change.

Conclusion: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

Keywords: Inter-reader agreement; Liver; Proton density fat fraction (PDFF); Quantitative imaging biomarker; Region of interest; Reproducibility.

Publication types

  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural

MeSH terms

  • Adipose Tissue / diagnostic imaging
  • Adipose Tissue / pathology
  • Cross-Sectional Studies
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Liver / diagnostic imaging
  • Liver / pathology
  • Longitudinal Studies
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Non-alcoholic Fatty Liver Disease / diagnostic imaging*
  • Non-alcoholic Fatty Liver Disease / pathology
  • Observer Variation
  • Prospective Studies
  • Protons

Substances

  • Protons