Diagnostic Accuracy of 2-Dimensional Shear Wave Elastography for the Staging of Liver Fibrosis: A Meta-analysis

J Ultrasound Med. 2019 Mar;38(3):733-740. doi: 10.1002/jum.14760. Epub 2018 Aug 31.

Abstract

Objectives: To evaluate the overall accuracy of 2-dimensional shear wave elastography (SWE) for the staging of liver fibrosis.

Methods: Literature databases and conference abstracts were searched from 2000 to September 2017. Sensitivity, specificity, and other information were extracted from the included studies. Methodological quality was assessed with Quality Assessment of Diagnostic Accuracy Studies 2 tools. Data were synthesized by a bivariate hierarchical model.

Results: The summary sensitivity and specificity were 0.85 (95% confidence interval [CI], 0.80-0.89) and 0.79 (95% CI, 0.72-0.85) for fibrosis stage F≥2, 0.90 (95% CI, 0.87-0.93) and 0.85 (95% CI, 0.80-0.89) for F≥3, and 0.89 (95% CI, 0.84-0.93) and 0.92 (95% CI, 0.89-0.95) for F=4, respectively. The areas under the summary receiver operating characteristic curve for F≥2, F≥3, and F=4 was 0.81, 0.77, and 0.84.

Conclusions: Two-dimensional SWE is a good noninvasive method for the diagnosis of substantial liver fibrosis and cirrhosis. Further studies are needed to assess severe fibrosis and to perform head-to-head comparisons of 2-dimensional SWE and other imaging modalities for the evaluation of liver fibrosis.

Keywords: 2-dimensional shear wave elastography; fibrosis staging; liver fibrosis; meta-analysis.

Publication types

  • Meta-Analysis

MeSH terms

  • Databases, Factual
  • Elasticity Imaging Techniques / methods*
  • Humans
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Cirrhosis / diagnostic imaging*
  • Liver Cirrhosis / pathology
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Severity of Illness Index