Objectives: To compare the performance of critical care providers with that of electroencephalography experts in identifying seizures using quantitative electroencephalography display tools.
Design: Diagnostic accuracy comparison among healthcare provider groups.
Setting: Multispecialty quaternary children's hospital in Canada.
Subjects: ICU fellows, ICU nurses, neurophysiologists, and electroencephalography technologists.
Intervention: Two-hour standardized one-on-one training, followed by a supervised individual review of 27 continuous electroencephalography recordings with the task of identifying individual seizures on eight-channel amplitude-integrated electroencephalography and color density spectral array displays.
Measurements and main results: Each participant reviewed 27 continuous electroencephalograms comprising 487 hours of recording containing a total of 553 seizures. Performance for seizure identification was compared among groups using a nested model analysis with adjustment for interparticipant variability within groups and collinearity among recordings. Using amplitude-integrated electroencephalography, sensitivity for seizure identification was comparable among ICU fellows (83.8%), ICU nurses (73.1%), and neurophysiologists (81.5%) but lower among electroencephalographic technologists (66.7%) (p = 0.003). Using color density spectral array, sensitivity was comparable among ICU fellows (82.4%), ICU nurses (88.2%), neurophysiologists (83.3%), and electroencephalographic technologists (73.3%) (p = 0.09). Daily false-positive rates were also comparable among ICU fellows (2.8 for amplitude-integrated electroencephalography, 7.7 for color density spectral array), ICU nurses (4.2, 7.1), neurophysiologists (1.2, 1.5), and electroencephalographic technologists (0, 0) (p = 0.41 for amplitude-integrated electroencephalography; p = 0.13 for color density spectral array). However, performance varied greatly across individual electroencephalogram recordings. Professional background generally played a greater role in determining performance than individual skill or electroencephalogram recording characteristics.
Conclusions: Following standardized training, critical care providers and electroencephalography experts displayed similar performance for identifying individual seizures using both amplitude-integrated electroencephalography and color density spectral array displays. Although these quantitative electroencephalographic trends show promise as a tool for bedside seizure screening by critical care providers, these findings require confirmation in a real-world ICU environment and in daily clinical use.