Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography

J Biomech. 2018 Oct 26:80:63-71. doi: 10.1016/j.jbiomech.2018.08.030. Epub 2018 Aug 29.

Abstract

The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT poses challenges due to improved resolution and a larger region of interest (ROI). This study addresses the need to harmonize results across FE models. The aims are to establish the relationship between FE results as a function of boundary conditions and a range of tissue properties for the first-generation HR-pQCT system, and to determine appropriate model parameters for the second-generation HR-pQCT system. We implemented common boundary conditions and tissue properties on a large cohort (N = 1371), and showed the relationships were highly linear (R2 > 0.99) for yield strength and reaction force between FE models. Cadaver radii measured on both generation HR-pQCT with matched ROIs were used to back-calculate a tissue modulus that accounts for the increased resolution (61 µm versus 82 µm), resulting in a modulus of 8748 MPa for second-generation HR-pQCT to produce bone yield strength and reaction force equivalent to using 6829 MPa for first-generation HR-pQCT. Finally, in vivo scans (N = 61) conducted on both generations demonstrated that the larger ROI in the second-generation system results in stronger bone outcome measures, suggesting it is not advisable to convert FE results across HR-pQCT generations without matching ROIs. Together, these findings harmonize FE results by providing a means to compare findings with different boundary conditions and tissue properties, and across scanner generations.

Keywords: Bone microarchitecture; Bone mineral density; Bone strength; Finite element analysis; High-resolution peripheral quantitative computed tomography; Micro-FE.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Bone Density
  • Bone and Bones
  • Cadaver
  • Female
  • Finite Element Analysis*
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Imaging, Three-Dimensional
  • Linear Models
  • Male
  • Middle Aged
  • Pressure
  • Radius / physiology*
  • Tomography, X-Ray Computed*
  • Treatment Outcome