Objectives: Tuberculous meningitis (TBM) is the severest form of tuberculosis, but current diagnostic tests are insensitive. Recent reports suggest simple modifications to conventional cerebrospinal fluid (CSF) Ziehl-Neelsen (ZN) staining may greatly improve sensitivity. We sought to define the performance of modified and conventional ZN stain for TBM diagnosis.
Methods: In hospitals in Vietnam, South Africa and Indonesia we conducted a prospective study of modified ZN with or without cytospin, conventional ZN smear, GeneXpert, and culture on CSF in adults with suspected TBM.
Results: A total of 618 individuals were enrolled across 3 sites. Compared with the TBM clinical diagnostic gold standard for research (definite probable or possible TBM), sensitivity of conventional ZN and modified ZN with cytospin were 33.9% and 34.5% respectively (p = 1.0 for the difference between tests), compared with culture 31.8% and Xpert 25.1%. Using culture as a reference, sensitivities of conventional ZN, modified ZN with cytospin, and Xpert were 66.4%, 67.5%, and 72.3%, respectively. Higher CSF volume and lactate, and lower CSF:blood glucose ratio were independently associated with microbiologically confirmed TBM.
Conclusions: Modified ZN stain does not improve diagnosis of TBM. Currently available tests are insensitive, but testing large CSF volumes improves performance. New diagnostic tests for TBM are urgently required.
Keywords: Cytospin; Diagnosis; Tuberculous meningitis; Xpert MTB/RIF; Ziehl–Neelsen stain.