Comparison of Modern Rigid Fixation Plating Outcomes for Segmental Mandibular Microvascular Reconstruction

Laryngoscope. 2019 May;129(5):1081-1086. doi: 10.1002/lary.27406. Epub 2018 Oct 3.

Abstract

Objectives/hypothesis: New advances in osseous microvascular mandibular rigid fixation are being employed at many institutions. These include standardized prebent/preformed reconstruction plates as well as computer-aided design/computer-aided manufacturing (CAD/CAM) custom plates that are patient specific. Our goal was to assess and compare the outcomes of both of these new technologies when utilized for mandibular microvascular reconstruction.

Study design: Retrospective chart review.

Methods: Subjects were categorized into two groups according to their mandibular rigid fixation technique: group 1 = prebent/preformed plates and group 2 = CAD/CAM custom plates. Primary outcome measures were 1) perioperative complications (defined as deep tissue infection, wound dehiscence resulting in bone exposure, and/or plate exposure) and 2) reoperation rates for mandibular hardware failure/explantation. Statistical analysis consisted of χ2 , Fisher exact test, and multivariable regression models.

Results: A total of 142 subjects underwent microvascular mandibular reconstruction in a 6-year period. Eighty-nine subjects utilized prebent/preformed plates, and 53 employed CAD/CAM custom plates. Perioperative complications occurred in 32 of 89 (35.9%) subjects with prebent/preformed plates and 11 of 53 (20.7%) subjects using CAD/CAM custom plates. Reoperation requiring hardware explantation occurred in 18 of 89 (20.2%) subjects and three of 53 (5.6%) using CAD/CAM custom plates. Statistical comparison of perioperative complications between the two groups approached significance (P = .0556), and the rate of reoperation was significant favoring CAD/CAM implants (P = .0180).

Conclusions: In our experience, CAD/CAM custom plates utilized for rigid fixation during microvascular mandibular reconstruction demonstrated fewer complications and statistically lower reoperation rates when compared with prebent/preformed plates.

Level of evidence: 2c Laryngoscope, 129:1081-1086, 2019.

Keywords: Rigid fixation; computer-aided design and computer-aided manufacturing; mandibular reconstruction; plating.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Plates*
  • Computer-Aided Design*
  • Female
  • Humans
  • Male
  • Mandibular Reconstruction / methods*
  • Microvessels / surgery*
  • Middle Aged
  • Retrospective Studies
  • Treatment Outcome
  • Vascular Surgical Procedures / methods
  • Young Adult