Objectives: We sought to determine the 1-year clinical follow-up in patients treated with the thin strut (71 μm) bioabsorbable polymer-coated sirolimus-eluting stent (BP-SES) vs durable coating everolimus eluting stent (DP-EES) in daily clinical routine.
Background: Presence of durable polymers may be associated with late/very late stent thrombosis occurrence and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety.
Methods: Interventional Cardiology Network Registry is a prospective, multicenter, observational registry of 21,400 consecutive patients treated with PCI since 2010. We analyzed 4,670 patients treated with either a BP-SES (ALEX, Balton, Poland) or DP-EES (XIENCE, Abbott, USA) with available 1-year clinical follow-up using propensity-score matching. Outcomes included target vessel revascularization (TVR) as efficacy outcome and all cause death, myocardial infarction (MI), and definite/probable stent thrombosis as safety outcomes.
Results: After propensity score matching, 1,649 patients treated with BP-SES and 1,649 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between both groups. There was no significant difference between tested groups in in-hospital mortality. One-year follow-up demonstrated comparable efficacy outcome, TVR (BP-SES 5.9% vs DP-EES 4.6% P = 0.45), as well as comparable safety outcomes, all cause death, MI and definite/probable stent thrombosis.
Conclusions: In this multicenter registry, the BP-SES thin strut biodegradable polymer-coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1-year after implantation to the DP-EES. These data support the relative safety and efficacy of DP-SES in a broad range of patients undergoing percutaneous coronary intervention.
Keywords: Bioresorbable polymer; Drug-Eluting Stents; Percutaneous Coronary Intervention.