Purpose: The purpose of this retrospective study is to evaluate the role of echo-color-Doppler (ECD) imaging in identifying a series of characteristics pursuant to aesthetic filling material such as their degree of absorbability and their potential complications which include their propensity to stimulate the formation of encapsulated foreign-body granulomas. In the latter case, ECD can be of aid by giving indication for surgical therapy.
Materials and methods: Over a 4-year period, we studied 180 patients (60 ♂) who underwent an aesthetic medical/surgical treatment. We used ECD to evaluate the implant material, its thickness, the injection site, the integrity of dermal layers and the presence of any associated complications.
Results: In 97% (174/180) of our patients, we were able to identify the type of material used; furthermore, 57% of patients had a hyaluronic acid implant, 14% a lipofilling and 29% a non-absorbable filler (with 10% of silicone). In 6/180 (3%), we could not recognize the material used; 89% (161/180) of our patients presented post-injection complications; moreover, 67% showed peri-implant dermal-hypodermal thickening areas with adjacent lymphostasis, 6% displayed an abnormal implant site, and 17% showed inflammation with encapsulated foreign-body granulomas that required subsequent surgical excision. Biopsy samples were obtained from 37/180 patients (21%); among these, 31 patients had an ECD evidence of granuloma and on 6 patients we were not able to define the injected material. Histopathological examination identified 29 granulomas, 5 sterile abscesses and 3 chronic inflammations in the absence of granuloma. ECD showed an overall 78% diagnostic accuracy, with 90% sensitivity and 37% specificity in detecting filler granulomas.
Conclusion: ECD is a low-cost technique that allows to identify filling materials and to assess the complications of an esthetic medical/surgical treatment.
Keywords: Color-Doppler high-resolution ultrasound; Filler; Granuloma; Skin lesion; Skin ultrasound.