Objective: Immunoblot (IB) methods are widely used to detect myositis-specific autoantibodies (MSAs); however, false-positive results are common. In this study, we aimed to determine whether associating the anti-nuclear antibody (ANA) IIF pattern may help to improve the specificity of MSA detection by IB in patients with idiopathic inflammatory myositis (IIM).
Methods: Serum samples from 104 patients presenting with muscle weakness/myalgia and positive to at least one MSA by IB (MYOS12 Diver and MIOS7 Diver, D-tek) were tested for ANAs on HEp-2000 cells (Immuno Concepts). The chi-square test was used to analyse the concordance of the MSA result and its corresponding pattern by ANA testing between patients with and without IIM.
Results: Eighty-three of the 104 patients had a diagnosis of definite IIM, while in 21 cases, patients were affected by other autoimmune diseases or various non-systemic diseases. Forty nine of 83 (59%) patients in the IIM group and 4/21 (19%) in the non-IIM group showed a concordance between ANA pattern and MSAs by IB (P < 0.001). MSA monopositivity was significantly associated with IIM (91.6%) compared with 61.9% in the non-IIM group (P = 0.0005).
Conclusions: Considering both the MSA result and its corresponding pattern by ANA testing may help to improve the specificity of MSA detection by IB and to confirm the diagnosis of MSA-associated IIM. The monopositivity of MSAs is an important additional tool to validate IB results.
Keywords: ANA pattern; IIM; MSA; algorithm; antibody; combination; immunoblot; immunofluorescence; myositis; specificity.
© The Author(s) 2019. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For permissions, please email: [email protected].