Efficacy of Per-oral Methylene Blue Formulation for Screening Colonoscopy

Gastroenterology. 2019 Jun;156(8):2198-2207.e1. doi: 10.1053/j.gastro.2019.02.001. Epub 2019 Feb 10.

Abstract

Background & aims: Topically applied methylene blue dye chromoendoscopy is effective in improving detection of colorectal neoplasia. When combined with a pH- and time-dependent multimatrix structure, a per-oral methylene blue formulation (MB-MMX) can be delivered directly to the colorectal mucosa.

Methods: We performed a phase 3 study of 1205 patients scheduled for colorectal cancer screening or surveillance colonoscopies (50-75 years old) at 20 sites in Europe and the United States, from December 2013 through October 2016. Patients were randomly assigned to groups given 200 mg MB-MMX, placebo, or 100 mg MB-MMX (ratio of 2:2:1). The 100-mg MB-MMX group was included for masking purposes. MB-MMX and placebo tablets were administered with a 4-L polyethylene glycol-based bowel preparation. The patients then underwent colonoscopy by an experienced endoscopist with centralized double-reading. The primary endpoint was the proportion of patients with 1 adenoma or carcinoma (adenoma detection rate [ADR]). We calculated odds ratios (ORs) and 95% confidence intervals (CIs) for differences in detection between the 200-mg MB-MMX and placebo groups. False-positive (resection rate for non-neoplastic polyps) and adverse events were assessed as secondary endpoints.

Results: The ADR was higher for the MB-MMX group (273 of 485 patients, 56.29%) than the placebo group (229 of 479 patients, 47.81%) (OR 1.46; 95% CI 1.09-1.96). The proportion of patients with nonpolypoid lesions was higher in the MB-MMX group (213 of 485 patients, 43.92%) than the placebo group (168 of 479 patients, 35.07%) (OR 1.66; 95% CI 1.21-2.26). The proportion of patients with adenomas ≤5 mm was higher in the MB-MMX group (180 of 485 patients, 37.11%) than the placebo group (148 of 479 patients, 30.90%) (OR 1.36; 95% CI 1.01-1.83), but there was no difference between groups in detection of polypoid or larger lesions. The false-positive rate did not differ significantly between groups (83 [23.31%] of 356 patients with non-neoplastic lesions in the MB-MMX vs 97 [29.75%] of 326 patients with non-neoplastic lesions in the placebo group). Overall, 0.7% of patients had severe adverse events but there was no significant difference between groups.

Conclusions: In a phase 3 trial of patients undergoing screening or surveillance colonoscopies, we found MB-MMX led to an absolute 8.5% increase in ADR, compared with placebo, without increasing the removal of non-neoplastic lesions. Clinicaltrials.gov no: NCT01694966.

Keywords: Chromoendoscopy; Colon Cancer; Endoscopy; Visualization.

Publication types

  • Clinical Trial, Phase III
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Administration, Oral
  • Aged
  • Colonoscopy / methods*
  • Colorectal Neoplasms / diagnosis*
  • Double-Blind Method
  • Early Detection of Cancer / methods*
  • Europe
  • Female
  • Humans
  • Image Enhancement / methods*
  • Internationality
  • Male
  • Methylene Blue / administration & dosage*
  • Middle Aged
  • Sensitivity and Specificity
  • United States

Substances

  • Methylene Blue

Associated data

  • ClinicalTrials.gov/NCT01694966