Objectives: To define the national rate of complete heart block (CHB) after transcatheter aortic valve replacement (TAVR) and its impact on procedural mortality, overall cost, and length of hospital stay.
Background: CHB leading to permanent pacemaker (PPM) implantation is one of the most common complications post TAVR. National data on the temporal trend of CHB post TAVR are lacking.
Methods: We queried the 2012-2014 National Inpatient Sample databases to identify all patients who underwent TAVR. Patients with preoperative pacemakers or implantable cardioverter-defibrillators were excluded. Association between CHB and outcomes, and overall trends in rate of CHB, PPM implantation, and inpatient mortality were examined.
Results: Of 35,500 TAVR procedures, 3,675 (10.4%) had CHB. Overall, occurrence of CHB significantly increased from 8.4% in 2012 to 11.8% in 2014 (adjusted OR per year: 1.23; 95% confidence interval [CI]: 1.17-1.29, P trend <0.001). During the same period, PPM implantation increased from 9.5 to 13.7% (adjusted OR per year: 1.22; 95% CI: 1.16-1.28, P trend <0.001). Patients with CHB had higher odds of in-hospital mortality when compared to patients without CHB (5.9% vs. 4.2%, adjusted OR: 1.32; 95% CI: 1.12-1.56; p = 0.001). Moreover, CHB was also associated with longer length of stay (LOS) and higher hospitalization cost.
Conclusions: There was a significant increase in rates of CHB and PPM implantation over the study period. Development of CHB was associated with increased in-hospital mortality, LOS, and hospitalization cost.
Keywords: National Inpatient Sample; TAVR; aortic stenosis; pacemaker.