Context.—: The College of American Pathologists periodically surveys laboratories to determine changes in cytopathology practices. We report the results of a 2016 survey concerning thyroid fine-needle aspiration (FNA).
Objective.—: To provide a cross-sectional survey of thyroid cytology practices in 2016.
Design.—: In 2016, a survey was sent to 2013 laboratories participating in the College of American Pathologists Non-Gynecologic Cytology Education Program (NGC-A) requesting data from 2015-2016 on several topics relating to thyroid FNA.
Results.—: A total of 878 laboratories (43.6% of 2013) replied to the survey. Radiologists performed the most thyroid FNA procedures in most laboratories (70%; 529 of 756), followed by endocrinologists (18.7%; 141 of 756), and most of these were performed under ultrasound guidance (92.1%; 699 of 759). A total of 32.6% of respondents (251 of 769) provided feedback on unsatisfactory rates for nonpathology providers who performed FNA. Intraprocedural adequacy assessment was primarily performed by attending pathologists (77.4%; 490 of 633) or cytotechnologists (28.4%; 180 of 633). Most laboratories used the Bethesda System for Reporting Thyroid Cytopathology (89.8%; 701 of 781) and performed molecular testing based on clinician request (68.1%; 184 of 270) rather than FNA diagnosis. Correlation of thyroid excisions with prior cytology results most often occurred retrospectively (38.4%; 283 of 737) and was used for pathologist interpretive quality assurance purposes.
Conclusions.—: These survey results offer a snapshot of national thyroid FNA cytology practices in 2016 and indicate that standardized cytology terminology is commonly used; pathologists perform most immediate adequacy assessments for thyroid FNA; laboratories use correlation statistics to evaluate pathologists' performance; and molecular tests are increasingly requested for indeterminate interpretations, but reflex molecular testing is rare.