Background: The recent growth of neuro-endovascular treatment has rekindled interest in the use of angiographic techniques for flow assessment. Aneurysm treatment with flow diverters is particularly amenable to such analysis. We analyze contrast time-density curves - recorded within aneurysms before (pre) and immediately after (post) flow diverter implantation to estimate six-month treatment outcomes.
Methods: Fifty-six patients with 65 aneurysms were treated with flow diverters at two institutions. A region of interest was drawn around the aneurysm perimeter in image sequences taken both pre and post angiography, and the temporal variation in grayscale intensity within the aneurysm (time-density curve) was recorded. Eleven parameters were quantified from each time-density curve. Aneurysm occlusion status was recorded six months post treatment. The change in parameters from pre to post treatment was statistically evaluated between aneurysm occluded and non-occluded groups.
Results: Of the 11 parameters, eight were significantly different before and immediately after flow diversion. Considering the entire data set, none of the parameters was statistically different between the occluded and non-occluded groups. However, subgroup analyses showed that four variables were significantly different between the aneurysm occluded and non-occluded groups. The sensitivity of these variables to predict aneurysm occlusion at six months ranged from 60% to 89%, while the specificity ranged from 55% to 70%.
Conclusions: Device-induced intra-aneurysmal flow alterations quantified by simple aneurysmal time-density curves can potentially be used to predict long-term outcomes of flow diversion. Large multi-center studies will be required to confirm these findings. Patient-to-patient variability in coagulation may need to be incorporated for clinically relevant predictive values.
Keywords: Concentration–time curve; contrast washout; time–density curve.