Continuous Hemodialysis Does Not Improve Graft Function During Ex Vivo Lung Perfusion Over 24 Hours

Transplant Proc. 2019 Jul-Aug;51(6):2022-2028. doi: 10.1016/j.transproceed.2019.03.042. Epub 2019 Jul 11.

Abstract

Background: Extended periods of ex vivo lung perfusion (EVLP) lead to several inadvertent consequences including accumulation of lactate and increasing electrolyte concentrations in the perfusate. We sought to determine whether continuous hemodialysis (CHD) of the perfusate would be a suitable modality for improving ionic homeostasis in extended EVLP without compromising functional outcomes.

Methods: Twelve porcine lungs were perfused using EVLP for 24 hours. All lungs were ventilated with negative pressure ventilation. Lungs in the treatment group (n = 6) underwent continuous hemodialysis of the perfusate. Functional parameters, edema formation, and histopathologic analysis were used to assess graft function. Electrolyte and lactate profiles were also followed to assess the efficiency of hemodialysis.

Results: Lungs in both treatment and control groups demonstrated stable and acceptable oxygenation to 24 hours. Lungs demonstrated a decrease in compliance over time. There was no difference in oxygenation and compliance between groups. CHD-EVLP lungs had higher pulmonary vascular resistance and pulmonary artery pressures. Despite increased perfusion pressures, weight gain at both 11 and 23 hours was not different between groups. Perfusate sodium and lactate concentrations were significantly lower in the CHD-EVLP group.

Conclusion: The addition of continuous hemodialysis to EVLP did not improve graft function up to 24 hours despite improved maintenance of perfusate composition.