Background: Influenza viruses is a leading cause of acute respiratory infection, placing a significant burden on healthcare. To reduce hospital transmission, patients clinically suspected of having influenza are isolated and offered empirical antiviral treatment. Here we report the use of a point of care test (POCT) for influenza viruses in an acute medical unit (AMU) at Queen Elizabeth Hospital Birmingham for patients presenting with influenza-like illness.
Methods: A PCR POCT was installed on AMU in Dec 17 - Mar 18 (period 2) and used to test any patient with influenza-like illness. We conducted an evaluation against influenza virus's data collected between Dec 16-Mar 17 (period 1) where no POCT was used. Four outcomes were measured: length of stay, oseltamivir utilisation, time to isolation and in-hospital cases of influenza viruses.
Results: There were 51 confirmed influenza virus cases in period 1 vs 666 in period 2. During period 2, the length of stay of patients presenting with influenza-like illness (2.4 vs 7.9 days) and time to isolation from receipt of a positive result (0.09 vs 1.26 days) was significantly shorter. The time to initial receipt of antivirals for patients with influenza virus was significantly quicker in period 2 (0.59 vs 1.1 days) and the total number of influenza virus cases identified after 72 h of admission was significantly lower (9% vs 51%).
Discussion: Following introduction of the POCT, there was an increase in appropriately targeted oseltamivir prescribing, shorter time to isolation, proportionally less post-72-h influenza virus cases and a reduction in length of stay of patients presenting with influenza-like illness.
Conclusions: Routine use of POCTs for viruses should be introduced into diagnostic pathways for acute respiratory illness, especially at the front door of hospitals.
Keywords: Acute medical unit; Emergency department; Influenza; PCR; Point of care testing.