Controlled emotional tactile stimulation during functional magnetic resonance imaging and electroencephalography

J Neurosci Methods. 2019 Nov 1:327:108393. doi: 10.1016/j.jneumeth.2019.108393. Epub 2019 Aug 12.

Abstract

Background: Tactile stimulation used to induce emotional responses is often not well-controlled. Replicating the same tactile stimulations across studies is difficult, compared to replicating visual and auditory modalities, which have standardized stimulus sets. Standardizing a stimulation method by replicating stimuli across studies is necessary to further elucidate emotional responses in neuroscience research using tactile stimulation.

The new method: We developed a tactile stimulation device. The device's ultrasonic motor and optical force sensor have the following criteria: (1) controls the physical property of stimuli, pressure, and stroking speed; (2) measures actual touch timing; (3) is safe to use in a magnetic resonance imaging (MRI) scanner; and (4) produces low noise in electroencephalography (EEG) and MRI.

Results: The noise level of the device's drive was sufficiently low. For the EEG experiment, we successfully used signal processing to diminish the commercial power supply noise. For functional MRI (fMRI) scans, we found <5% signal loss occurred during device rotation.

Comparison with existing method(s): We found no previous report about the noise level of a tactile stimulation device used to induce emotional responses during EEG and fMRI recordings. The signal loss rate was comparable with that of other robotic devices used in MRI scanners. Emotional feelings induced by this stimulation method were comparable with those elicited in other sensory modalities.

Conclusions: The developed device could be used for cognitive-affective neuroscience research when conducting EEG and fMRI scans. The device should aid in standardizing affective tactile stimulation for research in psychology and cognitive neuroscience.

Keywords: Affective touch; Cognetics; Electroencephalography; Emotion; Functional magnetic resonance imaging; Tactile stimulation device.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Electroencephalography / methods*
  • Emotions / physiology*
  • Female
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Physical Stimulation / instrumentation*
  • Physical Stimulation / methods
  • Touch Perception / physiology
  • Young Adult