Ipsilateral fracture of the shaft of femur and dislocation of the hip are very rare injuries. There always exists a dilemma regarding the treatment to reduce hip and choosing the appropriate method of fixation for a femur fracture, and a clear consensus is yet to be reached. A number of treatment methods such as the open reduction of femur and fixation followed by hip reduction have been tried so far. Ipsilateral fractures and dislocation occur due to high-energy trauma, and reduction of hip dislocation is considered as an orthopedic emergency. Here, we report a case in which we tried a novel approach by temporarily fixing the femur with an external fixator and reducing the hip dislocation. In the next sitting, we performed femur fixation in a closed manner with an interlocking intramedullary nail. We recommend that this novel method of treatment can be used for such types of injuries.
Keywords: fixator; fracture shaft of femur; ipsilateral hip dislocation; reduction.
Copyright © 2019, Rana et al.