Objectives: Stroke volume variation (SVV) has been used to predict fluid responsiveness. The authors hypothesized the changes in SVV induced by passive leg raising (PLR) might be an indicator of fluid responsiveness in patients with protective ventilation after cardiac surgery.
Design: A prospective single-center observational study.
Setting: A single cardiac surgery intensive care unit at a tertiary hospital.
Participants: A total of 123 patients undergoing cardiac surgery with hemodynamic instability. Tidal volume was set between 6 and 8 mL/kg of ideal body weight.
Interventions: PLR maneuver, fluid challenge.
Measurements and main results: SVV was continuously recorded using pulse contour analysis before and immediately after a PLR test and after fluid challenge (500 mL of colloid given over 30 min). Sixty-three (51.22%) patients responded to fluid challenge, in which PLR and fluid challenge significantly increased the SV and decreased the SVV. The decrease in SVV induced by PLR was correlated with the SV changes induced by fluid challenge. A 4% decrease in the SVV induced by PLR-discriminated responders to fluid challenge with an area under the curve of 0.90. The gray zone identified a range of SVV changes induced by PLR (between -3.94% and -2.91%) for which fluid responsiveness could not be predicted reliably. The gray zone included 15.45% of the patients. The SVV at baseline predicted fluid responsiveness with an area under the curve of 0.72.
Conclusions: Changes in the SVV induced by PLR predicted fluid responsiveness in cardiac surgical patients with protective ventilation.
Keywords: cardiac surgery; fluid responsiveness; hemodynamic monitoring; passive leg raising; protective ventilation; stroke volume variation.
Copyright © 2019 Elsevier Inc. All rights reserved.