Coronary Guidewire Fracture Into a Radial Artery Loop: A New Complication in the Transradial Era?

J Invasive Cardiol. 2019 Dec;31(12):E398.

Abstract

To date, complete fracture of a coronary wire into a radial artery loop has never been reported. We describe the occurrence of a new complication in the transradial intervention era.

Keywords: coronary guidewire fracture; radial artery loop; snare; wire fragment retrieval.

Publication types

  • Case Reports

MeSH terms

  • Aged, 80 and over
  • Catheterization, Peripheral* / adverse effects
  • Catheterization, Peripheral* / instrumentation
  • Catheterization, Peripheral* / methods
  • Coronary Angiography* / adverse effects
  • Coronary Angiography* / instrumentation
  • Coronary Angiography* / methods
  • Coronary Artery Disease / diagnosis
  • Equipment Failure
  • Female
  • Femoral Artery / surgery*
  • Humans
  • Intraoperative Complications* / diagnostic imaging
  • Intraoperative Complications* / etiology
  • Intraoperative Complications* / surgery
  • Radial Artery / surgery*
  • Treatment Outcome