Background: Although there have been several reports documenting complications related with transesophageal echocardiography (TEE) manipulation following cardiac surgery, there is a paucity of data regarding the safety of TEE used to guide catheter-based interventions. The aim of this study was to determine the prevalence, types and risk factors of complications associated with procedures requiring active TEE guidance.
Methods: This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, n = 1037) and high-risk (Mitraclip, LAAO and PVLC, n = 212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications.
Results: The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (P < .001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, P = .008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (OR = 1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, P < .001).
Conclusion: The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.
Copyright © 2019 Elsevier Inc. All rights reserved.