Clinical and radiographic outcomes with a posteriorly augmented glenoid for Walch B glenoids in anatomic total shoulder arthroplasty

J Shoulder Elbow Surg. 2020 May;29(5):e185-e195. doi: 10.1016/j.jse.2019.10.008. Epub 2020 Jan 7.

Abstract

Background: Osteoarthritis of the glenohumeral joint is often associated with posterior glenoid wear. The purpose of this study was to determine the clinical and radiographic outcomes of a posteriorly augmented glenoid in patients who have a Walch B glenoid deformity when treated with anatomic total shoulder arthroplasty (aTSA).

Methods: At total of 68 primary aTSA patients with osteoarthritis and a Walch B glenoid deformity were treated with an 8° posteriorly augmented glenoid. All patients were evaluated and underwent scoring preoperatively and at latest follow-up with 5 clinical outcome scoring metrics; active range of motion (ROM) was also measured. The mean follow-up period was 50 months, with a 2-year minimum follow-up period.

Results: All patients experienced significant improvements in pain and function following aTSA with a posteriorly augmented glenoid, and 90% of patients exceeded the minimal clinically important difference threshold for the clinical outcome metric scores and ROM measures. Two-thirds of patients exceeded the substantial clinical benefit threshold for the clinical outcome metrics and ROM. Preoperatively, the humeral head was posteriorly subluxated an average of 73% for each Walch B glenoid type, and at latest follow-up, all humeral heads were re-centered on the posteriorly augmented glenoid. Two patients with augmented glenoids who had Walch B2 glenoids underwent revision for aseptic glenoid loosening.

Discussion: Anatomic total shoulder arthroplasty patients with Walch B glenoids receiving an 8° posteriorly augmented wedge glenoid experienced excellent clinical and radiographic outcomes with a patient satisfaction rate greater than 97% and a low complication rate at a mean follow-up of 50 months. Humeral head centering was maintained for each type of Walch B glenoid.

Keywords: Shoulder; Walch B glenoid; anatomic; arthroplasty; augmented glenoid; glenoid; outcomes; radiolucent lines.

MeSH terms

  • Adult
  • Aged
  • Arthroplasty, Replacement, Shoulder*
  • Female
  • Humans
  • Humeral Head / surgery
  • Male
  • Middle Aged
  • Minimal Clinically Important Difference
  • Osteoarthritis / diagnostic imaging*
  • Osteoarthritis / surgery*
  • Patient Satisfaction
  • Prosthesis Design
  • Range of Motion, Articular
  • Retrospective Studies
  • Scapula / surgery
  • Shoulder Prosthesis