Objectives: This study aimed to investigate the safety and efficacy of ACURATE neo transcatheter aortic valve replacement (TAVR) facilitated by predilatation with the nonocclusive TrueFlow balloon catheter.
Background: Now that TAVR is moving forward, physicians have attempted to simplify and streamline the procedure and the so-called minimalist approach has become more popular.
Methods: We enrolled 142 patients (mean age: 82 ± 5 years, 61% female) in a prospective registry. Patients at low risk for intraprocedural third-degree atrioventricular block (AVB) underwent TAVR with the TrueFlow balloon without rapid pacing and without insertion of a provisional pacemaker (n = 121). The remaining 21 patients were predilated with rapid pacing using a provisional pacemaker and a standard balloon.
Results: Predilatation with the TrueFlow balloon was successful in all 121 patients. Postdilatation was less frequently required after predilatation with the TrueFlow (25% vs. 57%, p = .003). Moreover, median procedural duration with the TrueFlow was significantly shorter (42 [interquartile range, IQR: 34-53] vs. 55 [IQR: 46-61] min, p = .004). In-hospital outcomes were similar. At 30 days, there was no mortality, two (1%) patients had suffered a stroke and only four (3%) had required implantation of a new pacemaker.
Conclusion: Among patients with a low risk for intraprocedural third-degree AVB, the TrueFlow nonocclusive balloon catheter facilitates implantation of the ACURATE neo without the necessity of rapid pacing and a provisional pacemaker.
Keywords: aortic stenosis; conduction disorders; predilatation; procedure time; transcatheter aortic valve.