Timing and Trends of Right Atrial Pressure and Risk of Right Heart Failure After Left Ventricular Assist Device Implantation

J Card Fail. 2020 May;26(5):394-401. doi: 10.1016/j.cardfail.2020.01.013. Epub 2020 Jan 23.

Abstract

Background: Elevated right atrial pressure (RAP) is associated with poor outcomes after left ventricular assist device (LVAD) implantation. However, the optimal time for RAP measurement and the importance of resolution of right heart congestion prior to LVAD implantation remain unclear.

Methods and results: We performed a retrospective cohort study of 134 consecutive LVAD recipients from our institution. Congestion was defined as RAP ≥ 14 mmHg and was assessed at hospital admission and implant. The primary outcome was death or right ventricular assist device (RVAD) implantation. When stratified by congestion status at admission, congested and non-congested patients had similar event-free survival rates (hazard ratio [HR]: 1.2, 95% confidence interval [CI]: 0.6-2.6). However, when stratified at implant, congested patients had a higher rate death or RVAD implantation (HR: 2.5, 95% CI: 1.1-5.6). Patients were then divided into 4 groups based on their trajectory of congestion status: no congestion, resolved congestion, new congestion, or persistent congestion. Patients with no congestion and resolved congestion had similar outcomes, whereas patients with persistent congestion had a markedly increased rate of death or RVAD implantation (HR: 3.1, 95% CI: 1.3-7.6).

Conclusion: RAP at LVAD implantation is more strongly associated with postoperative outcomes than admission RAP. Patients not responsive to decongestive therapies, with persistently elevated RAP, represent a high-risk cohort for adverse outcomes following LVAD implantation.

Keywords: Heart failure; LVAD; hemodynamics.

MeSH terms

  • Atrial Pressure
  • Heart Failure* / epidemiology
  • Heart-Assist Devices*
  • Humans
  • Retrospective Studies
  • Treatment Outcome
  • Ventricular Dysfunction, Right* / epidemiology