Estimating ion confinement times from beam current transients in conventional and charge breeder ECRIS

Rev Sci Instrum. 2020 Jan 1;91(1):013304. doi: 10.1063/1.5128546.

Abstract

Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms-60 ms with a clear dependence on the ion charge-to-mass ratio-higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used for estimating the extracted RIB production efficiency.