Retinal and visual function in infants with non-accidental trauma and retinal hemorrhages

Doc Ophthalmol. 2020 Oct;141(2):111-126. doi: 10.1007/s10633-020-09756-1. Epub 2020 Feb 12.

Abstract

Purpose: To investigate retinal function and visual outcomes in infants with retinal hemorrhages due to non-accidental trauma (NAT).

Methods: This is a retrospective review of full-field or multifocal electroretinogram (ERG) recordings, visual acuity in log minimum angle of resolution (logMAR), clinical status, and neuroimaging. Multifocal ERGs from the central 40° were compared to corresponding fundus imaging. Visual acuity was measured by Teller cards at follow-up. ERGs were compared to controls recorded under anesthesia.

Results: Sixteen children met inclusion criteria (14 recorded during the acute phase and 2 during long-term follow-up). During the acute phase, ERGs (n = 4 full field; n = 10 multifocal ERG) showed abnormal amplitude, latency, or both in at least one eye. Ten subjects had significantly reduced responses in both eyes, 3 of which had an ERG dominated by a negative waveform (absent b-wave or P1). The remaining six subjects had responses in one eye that were near normal (≥ 50% of controls). ERGs were sometimes abnormal in local areas without hemorrhage. ERGs could be preserved in local areas adjacent to traumatic retinoschisis. Two subjects with reduced visual acuity had belated ERGs: One had an abnormal macular ERG and the other had a normal macular ERG implying cortical visual impairment. At follow-up, 10 of 14 subjects had significant visual acuity loss (≥ 0.7 age-corrected logMAR); four subjects had mild vision loss (≤ 0.5 age-corrected logMAR). Visual acuity outcome was not reliably associated with the fundus appearance in the acute phase. All subjects with a negative ERG waveform had severe vision loss on follow-up.

Conclusions: Retinal dysfunction was common during the acute phase of NAT. A near normal appearing fundus did not imply normal retinal function, and ERG abnormality did not always predict a poor visual acuity outcome. However, a negative ERG waveform was associated severe visual acuity loss. Potential artifacts of retinal hemorrhages and anesthesia could not fully account for multifocal ERG abnormalities. Retinal function can be preserved in areas adjacent to traumatic retinoschisis.

Keywords: Electroretinogram; Non-accidental trauma; Pediatric ophthalmology; Shaken baby syndrome.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Battered Child Syndrome / complications*
  • Child, Preschool
  • Electroretinography / methods
  • Female
  • Fundus Oculi
  • Hematoma, Subdural / diagnostic imaging
  • Hematoma, Subdural / etiology
  • Hematoma, Subdural / physiopathology*
  • Humans
  • Infant
  • Infant, Newborn
  • Male
  • Retina / physiopathology*
  • Retinal Hemorrhage / physiopathology*
  • Retrospective Studies
  • Tomography, Optical Coherence
  • Vision Disorders / physiopathology
  • Visual Acuity / physiology*