Corona Mortis Artery Pseudoaneurysm Causing Delayed Intermittent Hemoperitoneum After Robotic Radical Prostatectomy

Urology. 2020 Jul:141:e24-e25. doi: 10.1016/j.urology.2020.04.017. Epub 2020 Apr 21.

Abstract

Pseudoaneurysms are rare in urology and typically have a delayed presention with intermittent episodes of bleeding. We report a patient who presented with delayed and recurent hemoperitoneum following robotic assisted laparoscopic salvage radical prostatectomy and was found to have a pseudoaneurysm in the corona mortis artery.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Anatomic Variation
  • Aneurysm, False / complications*
  • Hemoperitoneum / etiology*
  • Humans
  • Iliac Artery
  • Laparoscopy*
  • Male
  • Postoperative Complications / etiology*
  • Prostatectomy / methods*
  • Recurrence
  • Robotic Surgical Procedures*