Tablet and web-based audiometry to screen for hearing loss in adults with cystic fibrosis

Thorax. 2020 Aug;75(8):632-639. doi: 10.1136/thoraxjnl-2019-214177. Epub 2020 May 14.

Abstract

Introduction: Individuals with chronic lung disease (eg, cystic fibrosis (CF)) often receive antimicrobial therapy including aminoglycosides resulting in ototoxicity. Extended high-frequency audiometry has increased sensitivity for ototoxicity detection, but diagnostic audiometry in a sound-booth is costly, time-consuming and requires a trained audiologist. This cross-sectional study analysed tablet-based audiometry (Shoebox MD) performed by non-audiologists in an outpatient setting, alongside home web-based audiometry (3D Tune-In) to screen for hearing loss in adults with CF.

Methods: Hearing was analysed in 126 CF adults using validated questionnaires, a web self-hearing test (0.5 to 4 kHz), tablet (0.25 to 12 kHz) and sound-booth audiometry (0.25 to 12 kHz). A threshold of ≥25 dB hearing loss at ≥1 audiometric frequency was considered abnormal. Demographics and mitochondrial DNA sequencing were used to analyse risk factors, and accuracy and usability of hearing tests determined.

Results: Prevalence of hearing loss within any frequency band tested was 48%. Multivariate analysis showed age (OR 1.127; (95% CI: 1.07 to 1.18; p value<0.0001) per year older) and total intravenous antibiotic days over 10 years (OR 1.006; (95% CI: 1.002 to 1.010; p value=0.004) per further intravenous day) were significantly associated with increased risk of hearing loss. Tablet audiometry had good usability, was 93% sensitive, 88% specific with 94% negative predictive value to screen for hearing loss compared with web self-test audiometry and questionnaires which had poor sensitivity (17% and 13%, respectively). Intraclass correlation (ICC) of tablet versus sound-booth audiometry showed high correlation (ICC >0.9) at all frequencies ≥4 kHz.

Conclusions: Adults with CF have a high prevalence of drug-related hearing loss and tablet-based audiometry can be a practical, accurate screening tool within integrated ototoxicity monitoring programmes for early detection.

Keywords: cystic fibrosis; respiratory Infection; systemic disease and lungs.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Audiometry
  • Computers, Handheld
  • Cross-Sectional Studies
  • Cystic Fibrosis / complications*
  • Cystic Fibrosis / therapy
  • Female
  • Hearing Loss / diagnosis*
  • Hearing Loss / epidemiology*
  • Humans
  • Internet
  • Male
  • Middle Aged
  • Prevalence
  • Risk Factors
  • Young Adult