Transcatheter aortic valve implantation and its impact on mitral valve geometry and function

J Card Surg. 2020 Sep;35(9):2185-2193. doi: 10.1111/jocs.14734. Epub 2020 Jul 11.

Abstract

Background: The aim of this study was to evaluate the impact of transcatheter aortic valve implantation (TAVI) on mitral valve geometry and function.

Methods: Eighty-four patients underwent TAVI. Forty-four (52%) patients received a balloon-expandable valve and 40 (48%) were implanted with a self-expandable valve. All patients underwent three-dimensional-volumetric transesophageal echocardiography of the mitral valve before and immediately after TAVI. A dedicated software was used for assisted semiautomatic measurement of mitral annular geometry.

Results: During systole, the anterior to posterior (AP) diameter was significantly reduced after the procedure (3.4 ± 0.5 cm vs 3.2 ± 0.5 cm; P < .05). The mitral annular area (10.8 ± 2.8cm2 vs 9.9 ± 2.6cm2 ; P < .05) as well as the tenting area (1.6 ± 0.7 cm2 vs 1.2 ± 0.6 cm2 ; P < .001) measured at mid-systole were reduced after TAVI. Diastolic measures were similar. Patients treated with balloon-expandable valves showed a significantly larger reduction in the AP diameter compared to self-expandable valves (-0.25 cm vs -0.11 cm; P < .05). The reduction of the annular area was higher in the balloon-expandable group (-1.2 ± 1.59 vs -0.22 ± 1.41; P < .05). Grade of mitral regurgitation did improve or remained stable after TAVI.

Conclusion: TAVI significantly impacts the mitral valve and mitral annular geometry and morphology. The choice of the prosthesis (balloon- vs self-expandable) may be relevant for those changes.

Keywords: 3D echocardiography; aortic valve replacement; mitral annular geometry; mitral regurgitation; transcatheter aortic valve implantation (TAVI).

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Prosthesis Implantation*
  • Heart Valve Prosthesis*
  • Humans
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery
  • Prosthesis Design
  • Transcatheter Aortic Valve Replacement*
  • Treatment Outcome