Comparison of ice pack test and single-fiber EMG diagnostic accuracy in patients referred for myasthenic ptosis

Neurology. 2020 Sep 29;95(13):e1800-e1806. doi: 10.1212/WNL.0000000000010619. Epub 2020 Aug 11.

Abstract

Objective: To compare the diagnostic accuracy of ice pack test (IPT) and single-fiber EMG (SF-EMG) in patients with suspected ocular myasthenia (OM) presenting with ptosis.

Methods: We studied consecutive patients referred for the clinical suspicion of OM. Patients underwent IPT and stimulated SF-EMG on the orbicularis oculi muscle. Receiver operating characteristic curve analysis was performed to determine the accuracy of IPT, SF-EMG, and their combination.

Results: We included 155 patients, 102 with OM and 53 with other diagnosis (OD). The IPT had a sensitivity of 86% (95% confidence interval [CI] 79-93) and a specificity of 79% (95% CI 68-90). SF-EMG showed a sensitivity of 94% (95% CI 89-98) and a specificity of 79% (95% CI 68-90). Overall, IPT and SF-EMG showed discordant results in 30 cases, 16 OM and 14 OD. The combination of IPT and SF-EMG, using the positivity of at least one test for OM diagnosis, increased the sensitivity to 98% (95% CI 95-100), reducing the specificity to 66% (95% CI 53-78), whereas using the positivity of both tests, we obtained a sensitivity of 82% (95% CI 75-90) and a specificity of 92% (95% CI 85-99). The negativity of both tests had a 94% (95% CI 87-100) negative predictive value. Comparison of the areas under the curve showed no differences in the diagnostic accuracy of IPT, SF-EMG, and their combinations.

Conclusions: IPT and SF-EMG have similar diagnostic accuracy in patients with OM presenting with ptosis. The negativity of both tests strongly suggests another diagnosis.

Classification of evidence: This study provides Class I evidence that both the IPT and SF-EMG accurately identify patients with OM.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Blepharoptosis / complications
  • Blepharoptosis / diagnosis*
  • Case-Control Studies
  • Diagnostic Techniques, Ophthalmological / standards*
  • Electromyography / methods
  • Electromyography / standards*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Muscle, Skeletal / physiopathology
  • Myasthenia Gravis / complications
  • Myasthenia Gravis / diagnosis*
  • Predictive Value of Tests*
  • Sensitivity and Specificity
  • Young Adult