Impact of number of run-off vessels on interwoven nitinol mesh stents patency in the femoropopliteal segment

J Geriatr Cardiol. 2020 Sep 28;17(9):561-565. doi: 10.11909/j.issn.1671-5411.2020.09.002.

Abstract

Objective: To evaluate the impact of run-off vessels number on the outcomes of Supera stent (Abbott Vascular, Santa Clara, Calif, USA) for treatment of femoropopliteal occlusive disease.

Methods: We retrospectively evaluated the medical records of 188 consecutive patients (mean age 68.2 ± 9.6 years, 100 males) undergone angiography and woven mesh stent implantation in femoral or popliteal arteries or both arterial segments, in our institution between January 1 2014 and January 1 2018. Target lesion revascularization and major adverse limb events at 12-month were evaluated comparing patients with 1-, 2- or 3-run-off vessels in the foot.

Results: Interventional success was achieved in 100%. Stent implantation involved in the femoral site in 56 patients (30.3%), the femoropopliteal in 92 patients (48.9%) and the popliteal site in 40 patients (21.3%). A significant improvement of ankle-brachial index (0.29 ± 0.6 vs. 0.88 ± 0.3, P < 0.001) and Rutherford class (5.3 ± 0.8 vs. 0.7 ± 1.9, P < 0.01) were observed before discharge. The median follow-up duration was 12.3 months (inter quartile range: 11.0 to 13.9). During the follow-up period, 52 patients (27.6%) had clinical events. Primary patency at 12 months was 72.4%. The primary patency significantly increased when the runoff status. Comparing the number of events among patients with different number of run-off vessels, a significant difference (P < 0.001) was observed for patients having one (24.0%) and two run-off vessels (15.0%).

Conclusions: The outcomes of Supera stent in femoropopliteal occlusive disease depend strictly on the number of run-off vessels.

Keywords: Drug-coated balloon; Femoro-popliteal restenosis; Stent.