Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices

J Heart Lung Transplant. 2021 Feb;40(2):128-137. doi: 10.1016/j.healun.2020.11.009. Epub 2020 Nov 22.

Abstract

Background: Patients with continuous-flow left ventricular assist devices (CF-LVADs) experience limitations in functional capacity and frequently, right ventricular (RV) dysfunction. We sought to characterize RV function in the context of global cardiopulmonary performance during exercise in this population.

Methods: A total of 26 patients with CF-LVAD (aged 58 ± 11 years, 23 males) completed a hemodynamic assessment with either conductance catheters (Group 1, n = 13) inserted into the right ventricle to generate RV pressure‒volume loops or traditional Swan‒Ganz catheters (Group 2, n = 13) during invasive cardiopulmonary exercise testing. Hemodynamics were collected at rest, 2 sub-maximal levels of exercise, and peak effort. Breath-by-breath gas exchange parameters were collected by indirect calorimetry. Group 1 participants also completed an invasive ramp test during supine rest to determine the impact of varying levels of CF-LVAD support on RV function.

Results: In Group 1, pump speed modulations minimally influenced RV function. During upright exercise, there were modest increases in RV contractility during sub-maximal exercise, but there were no appreciable increases at peak effort. Ventricular‒arterial coupling was preserved throughout the exercise. In Group 2, there were large increases in pulmonary arterial, left-sided filling, and right-sided filling pressures during sub-maximal and peak exercises. Among all participants, the cardiac output‒oxygen uptake relationship was preserved at 5.8:1. Ventilatory efficiency was severely abnormal at 42.3 ± 11.6.

Conclusions: Patients with CF-LVAD suffer from limited RV contractile reserve; marked elevations in pulmonary, left-sided filling, and right-sided filling pressures during exercise; and severe ventilatory inefficiency. These findings explain mechanisms for persistent reductions in functional capacity in this patient population.

Keywords: exercise; hemodynamics; left ventricular assist device; pressure-volume loops; right ventricle.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cardiac Catheterization
  • Cardiac Output / physiology*
  • Electrocardiography
  • Exercise / physiology*
  • Exercise Test
  • Female
  • Heart Failure / diagnosis
  • Heart Failure / physiopathology*
  • Heart Failure / therapy
  • Heart Ventricles / physiopathology*
  • Heart-Assist Devices*
  • Humans
  • Male
  • Middle Aged
  • Myocardial Contraction / physiology*
  • Stroke Volume
  • Ventricular Function, Right / physiology*