10-Year Follow-Up of Patients With Everolimus-Eluting Versus Bare-Metal Stents After ST-Segment Elevation Myocardial Infarction

J Am Coll Cardiol. 2021 Mar 9;77(9):1165-1178. doi: 10.1016/j.jacc.2020.12.059.

Abstract

Background: Outcomes data for a durable-polymer everolimus-eluting stent (EES) at extended long-term follow-up in patients with ST-segment elevation myocardial infarction (STEMI) are unknown.

Objectives: The aim of this study was to assess the 10-year outcomes of patients enrolled in the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction) trial.

Methods: The EXAMINATION-EXTEND (10-Years Follow-Up of the EXAMINATION Trial) study is an investigator-driven 10-year follow-up of the EXAMINATION trial, which randomly assigned 1,498 patients with STEMI in a 1:1 ratio to receive either EES (n = 751) or bare-metal stents (n = 747). The primary endpoint was a patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization. Secondary endpoints included a device-oriented composite endpoint of cardiac death, target vessel myocardial infarction, or target lesion revascularization; the individual components of the combined endpoints; and stent thrombosis.

Results: Complete 10-year clinical follow-up was obtained in 94.5% of the EES group and 95.9% of the bare-metal stent group. Rates of the patient-oriented composite endpoint and device-oriented composite endpoint were significantly reduced in the EES group (32.4% vs. 38.0% [hazard ratio: 0.81; 95% confidence interval: 0.68 to 0.96; p = 0.013] and 13.6% vs. 18.4% [hazard ratio: 0.72; 95% confidence interval: 0.55 to 0.93; p = 0.012], respectively), driven mainly by target lesion revascularization (5.7% vs. 8.8%; p = 0.018). The rate of definite stent thrombosis was similar in both groups (2.2% vs. 2.5%; p = 0.590). No differences were found between the groups in terms of target lesion revascularization (1.4% vs. 1.3%; p = 0.963) and definite or probable stent thrombosis (0.6% vs. 0.4%; p = 0.703) between 5 and 10 years.

Conclusions: At 10-year follow-up, EES demonstrated confirmed superiority in combined patient- and device-oriented composite endpoints compared with bare-metal stents in patients with STEMI requiring primary percutaneous coronary intervention. Between 5- and 10-year follow-up, a low incidence of adverse cardiovascular events related to device failure was found in both groups. (10-Years Follow-Up of the EXAMINATION Trial; NCT04462315).

Keywords: ST-segment elevation myocardial infarction; everolimus; randomized controlled trial; stent; stent thrombosis.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Drug-Eluting Stents / trends*
  • Dual Anti-Platelet Therapy / methods
  • Dual Anti-Platelet Therapy / trends
  • Everolimus / administration & dosage*
  • Female
  • Follow-Up Studies
  • Humans
  • Immunosuppressive Agents / administration & dosage*
  • Male
  • Metals*
  • Myocardial Revascularization / methods*
  • Myocardial Revascularization / mortality
  • Myocardial Revascularization / trends
  • Pregnancy
  • Prospective Studies
  • Prosthesis Design / methods
  • Prosthesis Design / mortality
  • Prosthesis Design / trends
  • ST Elevation Myocardial Infarction / mortality
  • ST Elevation Myocardial Infarction / physiopathology
  • ST Elevation Myocardial Infarction / therapy*
  • Single-Blind Method
  • Stents / trends
  • Time Factors

Substances

  • Immunosuppressive Agents
  • Metals
  • Everolimus

Associated data

  • ClinicalTrials.gov/NCT04462315