Report dose-to-medium in clinical trials where available; a consensus from the Global Harmonisation Group to maximize consistency

Radiother Oncol. 2021 Jun:159:106-111. doi: 10.1016/j.radonc.2021.03.006. Epub 2021 Mar 17.

Abstract

Purpose: To promote consistency in clinical trials by recommending a uniform framework as it relates to radiation transport and dose calculation in water versus in medium.

Methods: The Global Quality Assurance of Radiation Therapy Clinical Trials Harmonisation Group (GHG; www.rtqaharmonization.org) compared the differences between dose to water in water (Dw,w), dose to water in medium (Dw,m), and dose to medium in medium (Dm,m). This was done based on a review of historical frameworks, existing literature and standards, clinical issues in the context of clinical trials, and the trajectory of radiation dose calculations. Based on these factors, recommendations were developed.

Results: No framework was found to be ideal or perfect given the history, complexity, and current status of radiation therapy. Nevertheless, based on the evidence available, the GHG established a recommendation preferring dose to medium in medium (Dm,m).

Conclusions: Dose to medium in medium (Dm,m) is the preferred dose calculation and reporting framework. If an institution's planning system can only calculate dose to water in water (Dw,w), this is acceptable.

Keywords: Clinical trial; Dose calculation; Dose to medium, Dose to water; GHG; Radiation dosage.

Publication types

  • Review

MeSH terms

  • Consensus
  • Humans
  • Monte Carlo Method
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted*
  • Water*

Substances

  • Water