Radial Head Replacement for Acute Radial Head Fractures: Outcome and Survival of Three Implant Designs With and Without Cement Fixation

J Orthop Trauma. 2021 Jun 1;35(6):e202-e208. doi: 10.1097/BOT.0000000000001983.

Abstract

Objectives: To determine outcomes of radial head replacement (RHR) for acute fractures using 3 different implant designs with or without cement fixation.

Design: Retrospective.

Setting: Tertiary referral hospital.

Patients/participants: One hundred fourteen elbows underwent RHR for an acute radial head fracture using either (1) a nonanatomic design and smooth stem (n = 60), (2) a nonanatomic design with a grit-blasted, ingrowth, curved stem (n = 21), or (3) an anatomic design with a grit-blasted ingrowth straight stem (n = 33). Cemented (25%) or uncemented (75%) fixation was used at the discretion of the treating surgeon.

Intervention: RHR.

Main outcome measurements: The primary outcome was implant survivorship free of revision or removal for any reason. All elbows were evaluated clinically (the Mayo Elbow Performance Score and reoperations/complications) and radiographically.

Results: Fourteen implants (12%) were revised. Of elbows with a minimum 2-year clinical follow-up, the average Mayo Elbow Performance Score was 88. The rate of survivorship free from revision was 92% [95% confidence interval (CI) = 87%-98%] at 2 years, 90% (CI = 84%-96%) at 5 years and 84% (CI = 75%-94%) at 10 years. The differences in survivorship between the 3 implants did not reach statistical significance, but the nonanatomic design with a grit-blasted ingrowth curved stem had a hazard ratio of 4.6 (95% CI = 0.9%-23%) for failure. There were no differences in survivorship between cemented versus uncemented stems. For those elbows with a minimum of 2 years of radiographic follow-up, implant tilt was observed in 10 (16%) elbows and loosening in 16 (26%) elbows. Stress shielding was present in 19 (42%) of well-fixed implants.

Conclusions: RHR for acute trauma leads to survivorship greater than 80% at 10 years. Radiographic changes (loosening, stress shielding, and implant tilting) can be expected in a substantial portion of elbows at long-term follow-up.

Level of evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

MeSH terms

  • Elbow Joint* / diagnostic imaging
  • Elbow Joint* / surgery
  • Follow-Up Studies
  • Humans
  • Prosthesis Design
  • Radius Fractures* / diagnostic imaging
  • Radius Fractures* / surgery
  • Reoperation
  • Retrospective Studies
  • Treatment Outcome