Extracorporeal carbon dioxide removal with the Advanced Organ Support system in critically ill COVID-19 patients

Artif Organs. 2021 Dec;45(12):1522-1532. doi: 10.1111/aor.14044. Epub 2021 Sep 21.

Abstract

Disturbed oxygenation is foremost the leading clinical presentation in COVID-19 patients. However, a small proportion also develop carbon dioxide removal problems. The Advanced Organ Support (ADVOS) therapy (ADVITOS GmbH, Munich, Germany) uses a less invasive approach by combining extracorporeal CO2 -removal and multiple organ support for the liver and the kidneys in a single hemodialysis device. The aim of our study is to evaluate the ADVOS system as treatment option in-COVID-19 patients with multi-organ failure and carbon dioxide removal problems. COVID-19 patients suffering from severe respiratory insufficiency, receiving at least two treatments with the ADVOS multi system (ADVITOS GmbH, Munich, Germany), were eligible for study inclusion. Briefly, these included patients with acute kidney injury (AKI) according to KDIGO guidelines, and moderate or severe ARDS according to the Berlin definition, who were on invasive mechanical ventilation for more than 72 hours. In total, nine COVID-19 patients (137 ADVOS treatment sessions with a median of 10 treatments per patient) with moderate to severe ARDS and carbon dioxide removal problems were analyzed. During the ADVOS treatments, a rapid correction of acid-base balance and a continuous CO2 removal could be observed. We observed a median continuous CO2 removal of 49.2 mL/min (IQR: 26.9-72.3 mL/min) with some treatments achieving up to 160 mL/min. The CO2 removal significantly correlated with blood flow (Pearson 0.421; P < .001), PaCO2 (0.341, P < .001) and HCO 3 - levels (0.568, P < .001) at the start of the treatment. The continuous treatment led to a significant reduction in PaCO2 from baseline to the last ADVOS treatment. In conclusion, it was feasible to remove CO2 using the ADVOS system in our cohort of COVID-19 patients with acute respiratory distress syndrome and multiorgan failure. This efficient removal of CO2 was achieved at blood flows up to 300 mL/min using a conventional hemodialysis catheter and without a membrane lung or a gas phase.

Keywords: ADVOS; ARDS; COVID-19; extracorporeal CO2 removal (ECCO2R); multiple organ support.

Publication types

  • Observational Study

MeSH terms

  • Aged
  • COVID-19 / blood
  • COVID-19 / diagnosis
  • COVID-19 / physiopathology
  • COVID-19 / therapy*
  • Carbon Dioxide / blood*
  • Critical Illness
  • Extracorporeal Circulation / adverse effects
  • Extracorporeal Circulation / instrumentation*
  • Female
  • Humans
  • Lung / physiopathology*
  • Male
  • Middle Aged
  • Multiple Organ Failure / blood
  • Multiple Organ Failure / diagnosis
  • Multiple Organ Failure / physiopathology
  • Multiple Organ Failure / therapy*
  • Renal Dialysis / adverse effects
  • Renal Dialysis / instrumentation*
  • Respiration, Artificial* / adverse effects
  • Time Factors
  • Treatment Outcome

Substances

  • Carbon Dioxide