Diagnostic performance and clinical implications of rapid SARS-CoV-2 antigen testing in Mexico using real-world nationwide COVID-19 registry data

PLoS One. 2021 Aug 31;16(8):e0256447. doi: 10.1371/journal.pone.0256447. eCollection 2021.

Abstract

Background: SARS-CoV-2 testing capacity is important to monitor epidemic dynamics and as a mitigation strategy. Given difficulties of large-scale quantitative reverse transcription polymerase chain reaction (qRT-PCR) implementation, rapid antigen tests (Rapid Ag-T) have been proposed as alternatives in settings like Mexico. Here, we evaluated diagnostic performance of Rapid Ag-T for SARS-CoV-2 infection and its associated clinical implications compared to qRT-PCR testing in Mexico.

Methods: We analyzed data from the COVID-19 registry of the Mexican General Directorate of Epidemiology up to April 30th, 2021 (n = 6,632,938) and cases with both qRT-PCR and Rapid Ag-T (n = 216,388). We evaluated diagnostic performance using accuracy measures and assessed time-dependent changes in the Area Under the Receiver Operating Characteristic curve (AUROC). We also explored test discordances as predictors of hospitalization, intubation, severe COVID-19 and mortality.

Results: Rapid Ag-T is primarily used in Mexico City. Rapid Ag-T have low sensitivity 37.6% (95%CI 36.6-38.7), high specificity 95.5% (95%CI 95.1-95.8) and acceptable positive 86.1% (95%CI 85.0-86.6) and negative predictive values 67.2% (95%CI 66.2-69.2). Rapid Ag-T has optimal diagnostic performance up to days 3 after symptom onset, and its performance is modified by testing location, comorbidity, and age. qRT-PCR (-) / Rapid Ag-T (+) cases had higher risk of adverse COVID-19 outcomes (HR 1.54 95% CI 1.41-1.68) and were older, qRT-PCR (+)/ Rapid Ag-T(-) cases had slightly higher risk or adverse outcomes and ≥7 days from symptom onset (HR 1.53 95% CI 1.48-1.59). Cases detected with rapid Ag-T were younger, without comorbidities, and milder COVID-19 course.

Conclusions: Rapid Ag-T could be used as an alternative to qRT-PCR for large scale SARS-CoV-2 testing in Mexico. Interpretation of Rapid Ag-T results should be done with caution to minimize the risk associated with false negative results.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Antigens, Viral / analysis*
  • Area Under Curve
  • COVID-19 / diagnosis*
  • COVID-19 / epidemiology
  • COVID-19 / virology
  • COVID-19 Nucleic Acid Testing
  • COVID-19 Serological Testing*
  • Female
  • Hospitalization / statistics & numerical data
  • Humans
  • Male
  • Mexico / epidemiology
  • Middle Aged
  • Proportional Hazards Models
  • RNA, Viral / analysis
  • RNA, Viral / metabolism
  • ROC Curve
  • Registries
  • Retrospective Studies
  • SARS-CoV-2 / isolation & purification
  • SARS-CoV-2 / metabolism*
  • Sensitivity and Specificity
  • Young Adult

Substances

  • Antigens, Viral
  • RNA, Viral

Grants and funding

The publication of this article was supported by a grant from Secretaría de Educación, Ciencia, Tecnología e Innovación de la Ciudad de México CM-SECTEI/200/2020 “Red Colaborativa de Investigación Traslacional para el Envejecimiento Saludable de la Ciudad de México (RECITES).”