Objective: The relationship between volume and surgical outcomes has been shown for a variety of surgical procedures. The effects in abdominal aortic aneurysm repair have continued to be debated. Reliability adjustment has been used as a method to remove statistical noise from hospital-level outcomes. However, its impact on aortic aneurysm repair is not well understood.

Methods: We used prospectively collected data from the Vascular Quality Initiative to identify all patients who had undergone abdominal aortic aneurysm repair from 2003 to 2019. We first calculated the hospital-level risk-adjusted 30-day mortality rates. We subsequently used hierarchical logistic regression modeling to adjust for measurement reliability using empirical Bayes techniques. The effect of volume on risk- and reliability-adjusted mortality rates was then assessed using linear regression.

Results: Between 2003 and 2019, 67,073 abdominal aortic aneurysms were repaired, of which 11,601 (17.3%) were repaired with an open approach. The median annual volume was 7.4 (interquartile range, 3.0-13.3) for open repairs and 35.4 (interquartile range, 18.8-59.8) for endovascular repairs. Of the 223 hospitals that had performed open repairs during the study period, only 11 (4.9%) had performed ≥15 open repairs annually, and the risk-adjusted mortality rates varied from 0% to 75% across all centers. After reliability adjustment, the variability of the risk-adjusted mortality rates had decreased significantly to 1.3% to 8.2%. The endovascular repair risk-adjusted mortality rate variability had decreased from 0% to 14.3% to 0.3% to 2.8% after reliability adjustment. A decreasing trend in mortality was found with increasing an annual case volume for open repair with each additional annual case associated with a 0.012% decrease in mortality (P = .05); however, the relationship was not significant for endovascular repair (P = .793).

Conclusions: We found that most hospitals do not perform a sufficient number of annual cases to generate a reliable center-specific mortality rate for open aneurysm repair. Center-specific mortality rates for low-volume centers should be viewed with caution, because a substantial proportion of the variation for these outcomes will be statistical noise rather than true center-level differences in the quality of care.

Keywords: Aortic aneurysm; Mortality; Reliability.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Aortic Aneurysm, Abdominal / mortality
  • Aortic Aneurysm, Abdominal / surgery*
  • Blood Vessel Prosthesis Implantation / mortality*
  • Elective Surgical Procedures / mortality*
  • Female
  • Hospital Mortality / trends
  • Humans
  • Incidence
  • Male
  • Postoperative Complications / epidemiology*
  • Reproducibility of Results
  • Risk Assessment / methods*
  • Risk Factors
  • Survival Rate / trends
  • Time Factors