A Real-World Application of Liquid Biopsy in Metastatic Colorectal Cancer: The Poseidon Study

Cancers (Basel). 2021 Oct 13;13(20):5128. doi: 10.3390/cancers13205128.

Abstract

Background: First-line decision making is the key to the successful care of mCRC patients and RAS/BRAF status is crucial to select the best targeted agent. In hub centers, a relevant proportion of patients referred from small volume centers may not have standard tissue-based (STB) molecular results available at the time of the first visit (T0). Liquid biopsy (LB) may help circumvent these hurdles.

Methods: A monoinstitutional prospective head-to-head comparison of LB versus (vs.) STB testing was performed in a real-world setting. Selection criteria included: mCRC diagnosis with unknown RAS/BRAF status at T0, tumoral tissue archived in external centers, no previous treatment with anti-EGFR. At T0, patients underwent plasma sampling for LB testing and procedure for tissue recovery. RAS/BRAF genotyping was carried out by droplet digital PCR on circulating-tumoral (ct) DNA. The primary endpoint was the comparison of time to LB (T1) vs. STB (T2) results using the Mann-Whitney U test. Secondary endpoints were the concordance between LB and STB defined as overall percent agreement and the accuracy of LB in terms of specificity, sensitivity, positive and negative predictive value. We also performed an exploratory analysis on urinary (u) ctDNA.

Results: A total of 33 mCRC patients were included. Mean T1 and T2 was 7 and 22 days (d), respectively (p < 0.00001). T2 included a mean time for archival tissue recovery of 17 d. The overall percent agreement between LB and STB analysis was 83%. Compared to STB testing, LB specificity and sensitivity were 90% and 80%, respectively, with a positive predictive value of 94% and negative one of 69%. In detail, at STB and LB testing, RAS mutation was found in 45% and 42% of patients, respectively; BRAF mutation in 15%. LB results included one false positive and four false negative. False negative cases showed a significantly lower tumor burden at basal CT scan. Concordance between STB and uctDNA testing was 89%.

Conclusions: Faster turnaround time, high concordance and accuracy are three key points supporting the adoption of LB in routinary mCRC care, in particular when decision on first-line therapy is urgent and tissue recovery from external centers may require a long time. Results should be interpreted with caution in LB wild-type cases with low tumor burden.

Keywords: accuracy; concordance; first-line therapy; liquid biopsy; metastatic colorectal cancer; real-world; turnaround time.