A Score to Assess Mortality After Percutaneous Mitral Valve Repair

J Am Coll Cardiol. 2022 Feb 15;79(6):562-573. doi: 10.1016/j.jacc.2021.11.041.

Abstract

Background: Risk stratification for transcatheter edge-to-edge mitral valve repair (TEER) is paramount in the decision-making process for treating severe mitral regurgitation (MR).

Objectives: This study sought to create and validate a user-friendly score (MitraScore) to predict the risk of mortality in patients undergoing TEER.

Methods: The derivation cohort was based on a multicentric international registry that included 1,119 patients referred for TEER between 2012 and 2020. Score discrimination was assessed using Harrell's c-statistic, and the calibration was evaluated with the Gronnesby and Borgan goodness-of-fit test. An external validation was carried out in 725 patients from the GIOTTO registry.

Results: After multivariate analysis, we identified 8 independent predictors of mortality during the follow-up (2.1 ± 1.8 years): age ≥75 years, anemia, glomerular filtrate rate <60 mL/min/1.73 m2, left ventricular ejection fraction <40%, peripheral artery disease, chronic obstructive pulmonary disease, high diuretic dose, and no therapy with renin-angiotensin system inhibitors. The MitraScore was derived by assigning 1 point to each independent predictor. The c-statistic was 0.70. Per each point of the MitraScore, the relative risk of mortality increased by 55% (HR: 1.55; 95% CI: 1.44-1.67; P < 0.001). The discrimination and calibration for mortality prediction was better than those of EuroSCORE II (c-statistic 0.61) or Society of Thoracic Surgeons score (c-statistic 0.57). The MitraScore maintained adequate performance in the validation cohort (c-statistic 0.66). The score was also predictive for heart failure rehospitalization and was correlated with the probability of clinical improvement.

Conclusions: The MitraScore is a simple prediction algorithm for the prediction of follow-up mortality in patients treated with TEER.

Keywords: mortality; score; transcatheter edge-to-edge mitral valve repair.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Cardiac Catheterization / adverse effects*
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis Implantation / adverse effects*
  • Humans
  • Italy / epidemiology
  • Male
  • Mitral Valve / surgery*
  • Mitral Valve Insufficiency / mortality
  • Mitral Valve Insufficiency / physiopathology
  • Mitral Valve Insufficiency / surgery*
  • Postoperative Complications / mortality*
  • Registries*
  • Retrospective Studies
  • Risk Factors
  • Stroke Volume / physiology
  • Time Factors
  • Treatment Outcome