Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea

J Clin Sleep Med. 2022 Jun 1;18(6):1609-1615. doi: 10.5664/jcsm.9940.

Abstract

Study objectives: Sleep bruxism is characterized by rhythmic masticatory muscle activity (RMMA). This study aimed to determine the number and type of jaw muscles needed for a valid RMMA scoring in individuals with obstructive sleep apnea.

Methods: Ten individuals with obstructive sleep apnea (4 males; age, 50.1 ± 8.1 years) were included in this study. RMMA was scored using 1 or more of the following jaw muscles' electromyography (EMG) traces of polysomnography recordings: bilateral masseter and temporalis (4MT; the reference standard), unilateral masseter (1M), bilateral masseter (2M), unilateral temporalis (1T), bilateral temporalis (2T), unilateral chin EMG (1C), and bilateral chin EMG (2C).

Results: 1M, 2M, 1T, and 2T showed excellent agreement with 4MT (intraclass correlation coefficient = 0.751, 0.976, 0.815, and 0.950, respectively), while 1C and 2C presented fair agreement (intraclass correlation coefficient = 0.662 and 0.657). In addition, 2M and 2T displayed good sensitivity (87.8% and 72.0%) and positive predictive value (83.1% and 76.0%). In contrast, 1M and 1T had good sensitivity (88.4% and 87.8%) but fair positive predictive value (60.1% and 53.2%). 1C and 2C showed poor sensitivity (41.1% and 40.3%) and fair positive predictive value (62.9% and 60.6%).

Conclusions: Polysomnography with bilateral masseter or temporalis muscle EMG traces is regarded valid in RMMA scoring in individuals with obstructive sleep apnea. In contrast, unilateral masseter or temporalis muscle EMG showed only fair accuracy, and chin EMG had poor accuracy. Consequently, these montages cannot be recommended for RMMA scoring in the presence of obstructive sleep apnea.

Clinical trial registration: Registry: ClinicalTrials.gov; Name: The Effects of Oral Appliance Therapy on Masseter Muscle Activity in Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT02011425; Identifier: NCT02011425.

Citation: Li D, Aarab G, Lobbezoo F, Arcache P, Lavigne GJ, Huynh N. Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea. J Clin Sleep Med. 2022;18(6):1609-1615.

Keywords: chin; electromyography; masseter; obstructive sleep apnea; polysomnography; scoring accuracy; sleep bruxism; temporalis.

Publication types

  • Clinical Study

MeSH terms

  • Adult
  • Electromyography
  • Female
  • Humans
  • Male
  • Masseter Muscle / physiology
  • Masticatory Muscles / physiology
  • Middle Aged
  • Polysomnography
  • Sleep Apnea, Obstructive* / diagnosis
  • Sleep Apnea, Obstructive* / therapy
  • Sleep Bruxism* / complications
  • Sleep Bruxism* / diagnosis

Associated data

  • ClinicalTrials.gov/NCT02011425