Brachial plexus (BP) root injury often results in disability of the upper extremities. Improvements in high-frequency ultrasonography have enabled the visualization of BP nerve roots. This study was aimed at quantifying the diagnostic accuracy of ultrasonography in BP root injury at different stages post-trauma. A consecutive series of 170 patients with BP root injury between 2015 and 2019 were studied retrospectively and divided into three groups on the basis of time between injury and ultrasound examination (≤1 mo, 1-3 mo, >3 mo). Diagnosis of complete BP root injury under ultrasound was determined using a pre-defined criterion, including pseudomeningocele, retraction and rupture. Diagnostic accuracy was calculated based on surgical findings and intra-operative electrophysiological tests. Rates of detection of the cervical (C5-C8) and thoracic (T1) nerve roots under ultrasound were 99.4%, 99.4%, 99.4%, 95.9% and 79.4%, respectively. The sensitivity for complete BP root injury was 0.74, and the specificity was 0.91. No significant differences in sensitivity or specificity were observed across time stages. Ultrasound exhibited substantial consistency with surgical findings (κ = 0.70) for complete BP root injury at any stage post-injury. Ultrasound can be an optional method of diagnosis of complete BP root injury at an early stage post-injury.
Keywords: Brachial plexus; Nerve root injury; Retrospective studies; Trauma; Ultrasonography.
Copyright © 2022 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.