Real-world 6-month outcomes of minimally invasive aortic valve replacement with the EDWARDS INTUITY Elite valve system

Interact Cardiovasc Thorac Surg. 2022 Jul 9;35(2):ivac083. doi: 10.1093/icvts/ivac083.

Abstract

Objectives: We report on real-world safety and performance outcomes of minimally invasive rapid-deployment aortic valve replacement using the EDWARDS INTUITY Elite aortic valve system.

Methods: The study valve system was used in a European, prospective, multicentre post-market study. Various procedural, haemodynamic and clinical outcomes were evaluated through 6 months of post-implant.

Results: A total of 276 patients out of 280 (98.6%) enrolments were successfully implanted with the study valve using a minimally invasive approach between February 2016 and April 2017. Of these 276 patients, 240 (87%) underwent partial sternotomy and 36 (13%) patients underwent right thoracotomy. Mean cross-clamp time was 51.9 [standard deviation (SD): 16.0] min. From baseline to 6 months, the mean effective orifice area increased from 0.8 (SD: 0.3) to 1.8 (SD: 0.6) cm2 and the mean systolic gradient decreased from 46.0 (SD: 14.1) to 8.8 (SD: 3.7) mmHg. After 6 months, 70.7% and 26.4% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major paravalvular leak, reoperation and device explant at 6 months were 96.0%, 98.5%, 98.8%, 99.2% and 99.2%, respectively.

Conclusions: These results demonstrate that the study valve is a safe and effective choice for patients undergoing aortic valve replacement via minimally invasive surgery.

Name and registration of registry: MISSION (Assessing clinical outcomes using the EDWARDS INTUITY Elite Valve System in isolated AVR using Minimally InvaSive Surgery In a EurOpean multi-ceNter, active, post-market registry). clinicaltrials.gov ID #NCT02907463.

Keywords: Aortic valve replacement; Bioprosthesis; Haemodynamics; Heart valve; Rapid-deployment valve; Sutureless valve.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Bioprosthesis*
  • Heart Valve Prosthesis Implantation* / methods
  • Heart Valve Prosthesis*
  • Humans
  • Minimally Invasive Surgical Procedures / methods
  • Prospective Studies
  • Prosthesis Design
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT02907463

Grants and funding