Introduction: Onset of radial neck osteolysis (RNO) has been reported after radial head replacement (RHR), but data are sparse regarding impact and risk factors. We therefore conducted a retrospective study, 1) to quantify RNO after RHR, 2) to assess clinical and radiological impact, and 3) to identify risk factors.
Hypothesis: RNO prevalence is high, but functional impact is limited.
Material and method: A single-center retrospective study included all patients undergoing RHR for acute radial head fracture between 2008 and 2017: 53 patients, with a mean age of 53.8±15.7 years [range, 21-85 years]. At a minimum 2 years' follow-up, patients were assessed clinically on joint range of motion and Mayo Elbow Performance Score (MEPS) and radiologically on standard radiographs. Associations between RNO and various parameters were assessed.
Results: At a mean 46.7±19.8 months' follow-up [range, 24-84 months], RNO was found in 54.7% of cases (29/53), with mean 4.0 ±2.8mm distal extension [range, 1.2-13.4mm], corresponding to 13.4±7.3% of stem height [range, 2.7-27.7%]. RNO at last follow-up was not significantly associated with reduced flexion-extension (121.9° versus 114.0°; p=0.11), pronation-supination (152.6° versus 138.3°; p=0.25) or MEPS (84.7 versus 84.8; p=0.97), or with higher rates of postoperative complications (11/29 (37.9%) versus 7/24 (29.2%); p=0.782) or surgical revision (11/29 (37.9%) versus 10/24 (41.7%); p=0.503). RNO was significantly associated with cementless fixation (19/29 (65.5%) versus 7/24 (29.2%); p=0.01), unipolar prosthesis (21/29 (72.4%) versus 7/24 (29.2%); p=0.002), high filling-ratio, whether proximal (88% versus 77%; p=0.002), middle (84% versus 75%; p=0.007) or distal (69% versus 59%; p=0.032), and shorter radial stem (33.2mm versus 46.3mm; p=0.011). No demographic parameters showed significant association with RNO at last follow-up.
Conclusion: RNO was frequent after RHR, but without clinical or radiological impact in the present series. The risk factors identified here argue for involvement of stress shielding.
Level of evidence: IV, cohort study.
Keywords: Osteolysis; Radial head arthroplasty; Radial head prosthesis; Radial head replacement; radial neck.
Copyright © 2022 Elsevier Masson SAS. All rights reserved.