Transdermal estradiol gel is a commonly used menopausal hormone therapy. In research studies investigating the pharmacokinetics and clinical utility of transdermal estradiol gels, serum is often used to measure estradiol levels. Serum results only represent a moment in time during phlebotomy and thus provide little information and allow for limited inference unless serial measurements are performed. In contrast, dried urine may provide a representation of serum estradiol levels over a longer period of time, while also being non-invasive and easier to collect. The primary aim of this study was to evaluate a dried urine method to determine if it may be a viable option for evaluating estrogen exposure resulting from transdermal estradiol gel use. A secondary aim was to explore differences in the urinary estrogen profiles of premenopausal women on no therapy and postmenopausal women who were either on transdermal estradiol gel therapy or no therapy at all. The results of this study demonstrated that the expected dose-proportional changes in estrogen exposure can be observed in the urinary estrogen profile using a GC-MS/MS dried urine assay. The GC-MS/MS assay also showed the differences in the urinary estrogen profiles of premenopausal women, postmenopausal women on estrogen replacement therapy, and postmenopausal women on no therapy.
Keywords: Dried Urine; Estradiol; Estrone; Gas Chromatography; Sex Hormones; Steroid Hormones; Tandem Mass Spectrometry; Transdermal Estradiol Gel; Urinary Estradiol; Urinary Estrogen.
Copyright © 2022 The Author(s). Published by Elsevier Inc. All rights reserved.