A Randomised Phase II Clinical Trial Comparing the Deliverability and Acute Toxicity of Wide Tangent versus Volumetric Modulated Arc Therapy to the Breast and Internal Mammary Chain

Clin Oncol (R Coll Radiol). 2022 Aug;34(8):526-533. doi: 10.1016/j.clon.2022.03.020. Epub 2022 May 18.

Abstract

Aims: Inclusion of the internal mammary chain in the radiotherapy target volume (IMC-RT) improves disease-free and overall survival in higher risk breast cancer patients, but increases radiation doses to heart and lungs. Dosimetric data show that either modified wide-tangential fields (WT) or volumetric modulated arc therapy (VMAT) together with [AQ1]voluntary deep inspiration breath hold (vDIBH) keep mean heart doses below 4 Gy in most patients. However, the impact on departmental resources has not yet been documented. This phase II clinical trial compared the time taken to deliver IMC-RT using either WT and vDIBH or VMAT and vDIBH, together with planning time, dosimetry, set-up reproducibility and toxicity.

Materials and methods: Left-sided breast cancer patients requiring IMC-RT were randomised to receive either WT(vDIBH) or VMAT radiotherapy. The primary outcome was treatment time, powered to detect a minimum difference of 75 min (5 min/fraction) between techniques. The population mean displacement, systematic error and random error for cone beam computed tomography chest wall matches in three directions of movement were calculated. Target volume and organ at risk doses were compared between groups. Side-effects, including skin (Radiation Therapy Oncology Group), lung and oesophageal toxicity (Common Terminology Criteria for Adverse Events v 4.03) rates, were compared between the groups over 3 months. Patient-reported outcome measures, including shoulder toxicity at baseline, 6 months and 1 year, were compared.

Results: Twenty-one patients were recruited from a single UK centre between February 2017 and January 2018. The mean (standard deviation) total treatment time per fraction for VMAT treatments was 13.2 min (1.7 min) compared with 28.1 min (3.3 min) for WT(vDIBH). There were no statistically significant differences in patient set-up errors in between groups. The average mean heart dose for WT(vDIBH) was 2.6 Gy compared with 3.4 Gy for VMAT(vDIBH) (P = 0.13). The mean ipsilateral lung V17Gy was 32.8% in the WT(vDIBH) group versus 34.4% in the VMAT group (P = 0.2). The humeral head (mean dose 16.8 Gy versus 2.8 Gy), oesophagus (maximum dose 37.3 Gy versus 20.1 Gy) and thyroid (mean dose 22.0 Gy versus 11.2 Gy) all received a statistically significantly higher dose in the VMAT group. There were no statistically significant differences in skin, lung or oesophageal toxicity within 3 months of treatment. Patient-reported outcomes of shoulder toxicity, pain, fatigue, breathlessness and breast symptoms were similar between groups at 1 year.

Conclusion: VMAT(vDIBH) and WT(vDIBH) are feasible options for locoregional breast radiotherapy including the IMC. VMAT improves nodal coverage and delivers treatment more quickly, resulting in less breath holds for the patient. This is at the cost of increased dose to some non-target tissues. The latter does not appear to translate into increased toxicity in this small study.

Keywords: Breast radiotherapy; VMAT; heart-sparing radiotherapy; toxicity breast radiotherapy.

Publication types

  • Clinical Trial, Phase II
  • Randomized Controlled Trial

MeSH terms

  • Breast Neoplasms* / radiotherapy
  • Female
  • Humans
  • Organs at Risk / radiation effects
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods
  • Radiotherapy, Intensity-Modulated* / adverse effects
  • Radiotherapy, Intensity-Modulated* / methods
  • Reproducibility of Results
  • Unilateral Breast Neoplasms* / radiotherapy