Impact of Prosthetic Valve Regurgitation Assessed by Echocardiography and Magnetic Resonance Imaging on Long-Term Clinical Outcomes after TAVR

Cardiology. 2022;147(4):461-468. doi: 10.1159/000526336. Epub 2022 Aug 10.

Abstract

Background: Prosthetic valve regurgitation (PVR) impairs early and mid-term outcomes after transcatheter aortic valve replacement (TAVR). We explored the impact of PVR assessed by transthoracic echocardiography (TTE) and magnetic resonance imaging-regurgitation fraction (MRI-RF) on long-term clinical outcomes.

Methods: PVR was assessed by TTE applying the Valve Academic Research Consortium criteria and MRI-RF (from velocity-encoded phase contrast magnetic resonance sequence) in 424 patients.

Results: MRI-RF correlated modestly with the echocardiographic grades of PVR (Spearman's rank correlation coefficient = 0.32, p < 0.001). Using an MRI-RF ≥20% to define ≥ moderate PVR, echocardiography and MRI-RF agreed on PVR classification in 412 patients (97.2%; kappa statistic = 0.56, p < 0.001). Five-year mortality or reintervention was higher in patients with echocardiographic ≥ moderate PVR (83.3% vs. 45.0%, log rank p value = 0.002; HR [95% CI]: 3.18 [1.48-6.84]) as well as in patients with MRI-RF ≥20% (79.3% vs. 43.2%, log rank p value <0.001; HR [95% CI]: 2.68 [1.53-4.70]), while the outcomes of patients with echocardiographic mild PVR were not significantly different from those with none-trace PVR. In the two latter groups (echocardiographic < moderate PVR), MRI-RF ≥20% was associated with a significantly higher 5-year mortality or reintervention as compared with MRI-RF <20% (79.5% vs. 42.2%, log rank p value = 0.023; HR [95% CI]: 2.26 [1.10-4.65]).

Conclusions: Greater than mild PVR as defined by TTE or MRI-RF is associated with impaired long-term clinical outcomes after TAVR. MRI-RF can be used to further risk-stratify patients with echocardiographic less-than-moderate PVR.

Keywords: Aortic valve; Clinical outcomes; Imaging; Multimodality; Regurgitation; Transcatheter.

MeSH terms

  • Aortic Valve / surgery
  • Aortic Valve Insufficiency* / diagnostic imaging
  • Aortic Valve Insufficiency* / etiology
  • Aortic Valve Insufficiency* / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Echocardiography
  • Heart Valve Prosthesis*
  • Humans
  • Magnetic Resonance Imaging
  • Severity of Illness Index
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome