Technetium Tc 99m tilmanocept fails to detect sentinel lymph nodes in endometrial cancer

Gynecol Oncol Rep. 2022 Jul 30:43:101054. doi: 10.1016/j.gore.2022.101054. eCollection 2022 Oct.

Abstract

Background: Technetium Tc 99m tilmanocept is a synthetic radiotracer specifically designed for sentinel lymph node (SLN) mapping that has been FDA-approved in breast cancer, melanoma, and head and neck cancer. No published studies exist for the use of this radiotracer in endometrial cancer.

Objective: The primary objective was to determine the detection rate of bilateral SLNs in endometrial cancer with the concurrent use of technetium Tc 99m tilmanocept and ICG.

Methods: An open-label, single cohort, prospective feasibility study was conducted with participants receiving preoperative cervical injections of technetium Tc 99m tilmanocept followed by subsequent imaging and SPECT/CT. Intraoperative ICG injections were administered for all patients with near-infrared imaging used to visualize lymphatic vessels and nodes. A laparoscopic gamma counter was used to detect radioactive SLN intraoperatively.

Results: All six evaluated patients had FIGO grade 1 or 2 endometrioid histology. Stage IA/IB were in 33% and 66% of patients, respectively. Tilmanocept did not map any SLN in the first six patients but instead showed retention of the tracer in the cervical stroma, leading to study discontinuation for futility. ICG mapped bilateral SLN in all patients with the most common location being the external iliac region, followed by the obturator and common iliac areas. All patients had CD206 positive staining throughout the full wall thickness of ectocervix, transformation zone, endocervix, and lymphatic vessels. No patients experienced adverse events.

Conclusion: Technetium Tc 99m tilmanocept did not detect SLN in early stage endometrial cancers and is unlikely to improve bilateral detection rate compared to ICG alone. ICG remains a standard technique for SLN detection in low stage, low grade endometrial cancer.