Introduction: Clinicians often order the international normalized ratio (INR) and activated partial thromboplastin time (APTT) to evaluate for the possibility of inherited bleeding disorders despite sensitivities and specificities of 1%-2%. The most accurate tool to evaluate for bleeding disorders is a validated bleeding assessment tool (BAT). Our aim was to reduce coagulation testing by >50% in a large family practice in Ontario, Canada.
Methods: We conducted an implementation study from May 2016 to February 2020. Iterative interventions included introduction of a validated BAT into the electronic medical record (EMR); removal of the APTT as a prepopulated selection from the laboratory requisition; and education targeting family medicine teams and laboratory personnel. The primary outcome was the rate of pre- and post-APTT testing. Creatinine testing was the control. Data were analyzed via an interrupted time series analysis using Stata 13.
Results: Immediately following education of the laboratory personnel on coagulation testing, the APTT rate level dropped by 1.26 tests per 100 patient visits per month (p < 0.001) and was sustained until the end of the study. Meanwhile, the PT/INR and creatinine testing rate levels did not change (rate level = -0.02 per 100 visits per month, p = 0.79 and 0.49, p = 0.22 respectively). There was good uptake of the BAT following integration and 18/88 (20%) obtained a referral to hematology after BAT completion.
Conclusions: Multidisciplinary, iterative interventions reduced APTT testing and enabled the use of BATs to guide hematology referrals in a large family practice.
Keywords: hemostasis; hemostatic disorders; implementation science; international normalized ratio; partial thromboplastin time.
© 2022 The Authors. Research and Practice in Thrombosis and Haemostasis published by Wiley Periodicals LLC on behalf of International Society on Thrombosis and Haemostasis (ISTH).