Validation of combined carcinoembryonic antigen and glucose testing in pancreatic cyst fluid to differentiate mucinous from non-mucinous cysts

Surg Endosc. 2023 May;37(5):3739-3746. doi: 10.1007/s00464-022-09822-6. Epub 2023 Jan 19.

Abstract

Background: More accurate diagnosis of mucinous cysts will reduce the risk of unnecessary pancreatic surgery. Carcinoembryonic antigen (CEA) and glucose in pancreatic cyst fluid (PCF) can differentiate mucinous from non-mucinous pancreatic cystic neoplasms (PCN). The current study assessed the value of combined CEA and glucose testing in PCF.

Methods: Cross-sectional validation study including prospectively collected PCF from patients undergoing endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) and pancreatic surgery. We performed laboratory measurements for CEA and glucose and measured glucose levels by a hand glucometer. Primary outcome was diagnostic accuracy evaluated by receiver operator curves (ROC), sensitivity, specificity, positive, and negative predictive value (PPV, NPV).

Results: Overall, PCF was collected from 63 patients, including 33 (52%) with mucinous and 30 (48%) with non-mucinous PCN. Histopathology (n = 36; 57%), cytopathology (n = 2; 3%), or clinical and/or radiological diagnosis (n = 25; 40%) was used as reference standard. Combined CEA (cut-off ≥ 192 ng/ml) and laboratory glucose testing (cut-off ≤ 50 mg/dL) reached 92% specificity and 48% sensitivity, whereas either positive CEA (cut-off ≥ 20 ng/ml) or glucose testing (cut-off ≤ 50 mg/dL) showed 97% sensitivity and 50% specificity. Sensitivity and specificity were 80% and 68% for CEA ≥ 20 ng/mL versus 50% and 93% for CEA ≥ 192 ng/mL (the conventional cut-off level). Laboratory and glucometer glucose both reached 100% sensitivity and 60% and 45% specificity, respectively. None of the biomarkers and cut-offs reached a PPV exceeding 90%, whereas both glucose measurements had a NPV of 100% (i.e., high glucose excludes a mucinous cyst).

Conclusion: Combined CEA and glucose testing in PCF reached high specificity and sensitivity for differentiating mucinous from non-mucinous PCN. Glucose testing, whether alone or combined with the new CEA cut-off (≥ 20 ng/mL), reached > 95% sensitivity for mucinous cysts, whereas only glucose reached a NPV > 95%.

Keywords: Carcinoembryonic antigen (CEA); Diagnostic accuracy; Endoscopy: Endoscopic ultrasound diagnostic and therapeutic; Glucose; Hepatobiliary tract and spleen; Pancreatic cyst fluid; Pancreatic cystic neoplasms.

MeSH terms

  • Carcinoembryonic Antigen
  • Cross-Sectional Studies
  • Cyst Fluid / chemistry
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration
  • Glucose
  • Humans
  • Mucocele*
  • Pancreatic Cyst* / diagnostic imaging
  • Pancreatic Neoplasms* / diagnosis
  • Pancreatic Neoplasms* / pathology
  • Retrospective Studies

Substances

  • Carcinoembryonic Antigen
  • Glucose