Background: Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation.
Methods: In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms.
Results: 128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71).
Conclusions: The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.
Keywords: Catheter ablation; Cavotricuspid isthmus; PR interval; Typical atrial flutter.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.